Using the Right Piping Material for Your Plumbing Application

PEX can be spliced into existing pipe, including copper pipe, which makes it a great choice for additions and retrofits. PEX is durable enough for hot water applications, but it cannot be connected directly to the hot water heater. For hot water supply lines, it must be connected to an 18-inch section of copper or other hot-water-safe piping.

Learn More

Hydronic Heating Systems:Two-Pipe, Direct-Return System

Oct 18, 2015 · Two-Pipe, Direct-Return System In a two-pipe, direct-return system (Figure 7-5), hot water returns directly to the boiler from each heat-emitting unit. In other words, the hot-water supply and return mains are separate pipes. The heat- emitting units are connected to the supply and return lines by separate branches (Figure 7-6). Each heat-emitting unit represents the

Learn More

HOT WATER SYSTEMS - Complete Boiler Room Solutions

ASME Power Piping Code. Boiler Selection Considerations When a hot water system is laid out, all of the components must be selected to work together to achieve the design intent. The design intent could include criteria such as: system flexibility, maximum efficiency, heating/cooling, domestic hot water, heat storage,

Learn More

COMMERCIAL PIPING DIAGRAMS - Water Heaters for Residential

Gas Water Heaters; Electric Water Heaters; Indirect Water Heaters; Boilers & Volume Water Heaters; Storage Tanks; Resources. Spec, Manuals, & Parts Lists; Right Spec® Sizing & Cross Reference Tools; Revit® eF Series® Calculator; Tank Size Calculator; Piping Diagrams; Service Bulletins; Uniform Energy Factor (UEF) Warranty Center; Product

Learn More

Savings Project: Insulate Hot Water Pipes for Energy Savings

Starting at the water heater, measure lengths of insulation needed to cover all accessible hot water pipes, especially the first 3 feet of pipe from the water heater. It's also a good idea to insulate the cold-water inlet pipes for the first 3 feet. 2) Cut the pipe sleeve. Cut the insulation to the lengths needed. 3) Place the pipe sleeve.

Learn More

Resources for boiler codes and standards - Specifying Engineer

Apr 18, 2014 · ASME B31.1: Power Piping (2012 edition) covers nonboiler external piping from a boiler operating above 15 psi, including central and district heating piping systems that distribute the steam or hot water to buildings. ASME B31.1 also covers piping within buildings that exceeds the service limits of B31.9.

Learn More

Hot Water Recirculating Loop - Ask the Builder

Just before the loop enters the bottom of the hot water heater you might need to install a simple check valve. These are one-way valves. This valve will prohibit in-rushing cold water from the bottom of the hot water heater from flowing backwards through the loop when you open a hot water faucet somewhere within the system.

Learn More

Domestic Hot Water Service Systems - Design Procedure

The design of a hot water service system may follow the procedure: Determine the demand of hot water from the consumers - quantity and temperature. Select the type, capacity and heating surface of the calorifier - or heat exchanger. Hot water is normally supplied to fittings and their consumers at 50 - 60 oC.

Learn More

Inefficient Hot Water Piping Layouts Waste Hot Water

Sep 25, 2012 · There are three typical configurations for a hot water system: a central water heater (or boiler) with trunks and branches serving each use or group of uses; a central water heater (or boiler) with a circulation loop or heat traced trunk line and branches to each use; distributed water heaters (or boilers) located close to the uses they serve.

Learn More

What type of pex tubing to use for hot water heating with

The pipes are 3" in the boiler room and then taper down sequentially via reducers and tees to 3/4" as they run out toward the different Tees and radiators. The boiler has 1 1/4' coppers pipes that come out of it, which then feed into the 3" iron pipes in the boiler room.

Learn More

Design of a High-Temperature-Hot-Water-Plant Expansion | HPAC

The thermal-stress analysis was a key part of the plant design for a number of reasons. First, the piping system needed to meet stress requirements of ASME B31.1. The pipe was laid out to allow system expansion where possible to reduce system stresses. Second, the boiler inlet-flange and outlet-flange forces and moments needed to be analyzed.

Learn More

The Normal PSI Reading for a Hot Water Boiler System | Hunker

The standard cold water operating pressure of most U.S. and Canadian hot water boilers is 12 pounds per square inch (psi). If the boiler pressure drops below 12 psi, the valve will allow new water into the unit to bring up the pressure reading. Video of the Day. Hunker How - Turn an Empty Corner Into a Home Office.

Learn More

HOT WATER HEATING SYSTEM BASICS AND DIAGRAM | ALL ABOUT

Hot water heating systems (Figure below) transport heat by circulating heated water to a designated area. Heat is released from the water as it flows through the heating unit (coil, terminal). After heat is released, the water returns to the boiler to be reheated and recirculated. Low temperature hot water boilers are 250°F. High

Learn More

Hot Water Heating System - Design Procedure

An open expansion tank is only relevant for Low Pressured Hot Water - LPHW - systems. The pressure is limited by the highest location of the tank. The volume of an open expansion tank should be the double of the estimated expansion volume in the system. The formula below can be used for a hot water system heated from 7oC to 100oC (4%):

Learn More

Specifying high-temperature hot-water boilers and systems

The ASME Section Committee B31.1 also has total administrative jurisdiction and technical responsibility on the construction and installation of all non-boiler external piping and joints (NBEPs); this includes piping systems carrying steam, water, oil, gas, and air.

Learn More